{"id":4938,"date":"2022-04-28T09:22:51","date_gmt":"2022-04-28T13:22:51","guid":{"rendered":"https:\/\/armstronginternational.com.br\/?page_id=4938"},"modified":"2024-12-03T01:08:51","modified_gmt":"2024-12-03T06:08:51","slug":"evapack-recirculated-water","status":"publish","type":"page","link":"https:\/\/armstronginternational.com.br\/en\/industries\/data-centers\/evapack-recirculated-water\/","title":{"rendered":"EvaPack<sup>\u00ae<\/sup> Recirculated Water"},"content":{"rendered":"","protected":false},"excerpt":{"rendered":"","protected":false},"author":5,"featured_media":0,"parent":4805,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"_acf_changed":false,"_searchwp_excluded":"","footnotes":""},"class_list":["post-4938","page","type-page","status-publish","hentry"],"acf":{"banner_type":"medium","pull-up_page_content":"","video":"","banner_image":39586,"banner_heading":"EvaPack<sup>\u00ae<\/sup> Recirculated Water (RW) Series","banner_subhead":"","banner_paragraph":"","button_link":"","button_label":"","modules":[{"module":"full","content_type_1":"narrow","padding":"pad-bottom","background":"none","image_position":false,"image_1":null,"image_2":null,"video_file":null,"color":"","font_color":"","section_heading":"","module_content_1":"<h3>Configuration and Components for Armstrong International's EvaPack<sup>\u00ae<\/sup> RW Series<\/h3>\r\nEvaPack<sup>\u00ae<\/sup> Adiabatic Cooling and Humidification offers significant advantages for your data center, including low energy consumption, tailor-made sizing, easy maintenance and cleaning, and quick installation.","module_content_2":"","module_content_3":"","accordion":null,"content_connector":null,"download_box_heading":"","downloads":null,"menu_item":null},{"module":"downloads","content_type_1":"standard","padding":"pad-bottom","background":"none","image_position":false,"image_1":null,"image_2":null,"video_file":null,"color":"","font_color":"","section_heading":"","module_content_1":"<h3>Options for RW Configuration +<\/h3>\r\n<ul>\r\n \t<li>High efficiency integral droplet separator in PP material (requested for VDI 6022 hygienic configuration)<\/li>\r\n \t<li>Filling water pretreatment by U.V. lamp with 50\u03bcm and 5\u03bcm water filters<\/li>\r\n \t<li>Water high temperature alarm<\/li>\r\n \t<li>Air relative humidity sensor<\/li>\r\n \t<li>Air temperature sensor<\/li>\r\n \t<li>Multiple stage control with solenoid valves (up to 4 stage control)<\/li>\r\n \t<li>Water conductivity sensor<\/li>\r\n<\/ul>\r\n<h3>\u00a0Standard Components Supplied With EvaPack<sup>\u00ae<\/sup>\u00a0\u00a0 +<\/h3>\r\nNote: The EvaPack<sup>\u00ae<\/sup> control panel is required for all electrical devices.\r\n<ul>\r\n \t<li>Water basin with draining and overflow piping<\/li>\r\n \t<li>Evaporative cassettes (composed of EvaPack<sup>\u00ae<\/sup> evaporative pad and cassette frames in stainless steel AISI 304)<\/li>\r\n \t<li>Side and top frames in stainless AISI 304<\/li>\r\n \t<li>Irrigation piping<\/li>\r\n \t<li>Dispersion manifold(s)<\/li>\r\n \t<li>Water pump<\/li>\r\n \t<li>Manual adjustment gate valve(s)<\/li>\r\n \t<li>Water draining valve<\/li>\r\n \t<li>Solenoid water filling valve<\/li>\r\n \t<li>Water level sensos<\/li>\r\n<\/ul>\r\n<h3>Operation Sequences\u00a0\u00a0 +<\/h3>\r\nThis configuration is recommended when the available supplied water has low or medium hardness.\r\n\r\nFor additional information, please consult the EvaPack<sup>\u00ae<\/sup> IOM manual:\u00a0 EvaPack \u2122 Series Evaporative Pad Adiabatic Humidifier\/Cooler Installation for RW and DW Configuration.\r\n<p align=\"center\"><a href=\"https:\/\/armstronginternational.com.br\/sites\/default\/files\/resources\/files\/542-V11%20EvaPack_EN.pdf\">\u00a0Download Manual<\/a><\/p>\r\n\r\n<ul>\r\n \t<li>Water enters the basin, passing through the filling valve (1). The water level detector (7) controls the basin (2) filling, the pump (3) starting-up and the fill valve opening.<\/li>\r\n \t<li>The recirculation water pump (3) supplies water to the different dispersion manifolds (5). The water flow of each cassette (6) is adjusted with a manual gate valve (4). Calibrated orifices deliver water evenly over each media pad (6).<\/li>\r\n \t<li>Dry air passes through a corrugated bank of wetted cells media (6). Air is cooled and humidified.<\/li>\r\n \t<li>Excess water washes the evaporative pad, then falls (with minerals) into the water tank.<\/li>\r\n \t<li>Excess minerals are drained by the draining valve, minimizing water consumption and media scaling.<\/li>\r\n<\/ul>\r\n(image of operation sequences)\r\n\r\n<a href=\"https:\/\/armstronginternational.com.br\/humidification\">Products for Health and Humidification<\/a>","module_content_2":"","module_content_3":"","accordion":null,"content_connector":null,"download_box_heading":"Downloads","downloads":[{"download_label":"EvaPack<sup>\u00ae<\/sup>\u00a0 Brochure","download_link":"https:\/\/armstronginternational.com\/wp-content\/uploads\/sites\/9\/Broch_EvapackEvaporativePadAdiabatic_EN_599E_20221101.pdf"},{"download_label":"Scaleway DC5 Data Center Case Study","download_link":"https:\/\/armstronginternational.com\/wp-content\/uploads\/sites\/9\/CS_EvapackScalewayDC5_DataCenters.pdf"},{"download_label":"EvaPack<sup>\u00ae<\/sup> Evaporative Pad Humidifier IOM","download_link":"https:\/\/armstronginternational.com\/wp-content\/uploads\/sites\/9\/IOM_EvaPackEvaporativeHumidifier_542_EN_20200701.pdf"}],"menu_item":null},{"module":"side","content_type_1":"standard","padding":"pad-bottom","background":"none","image_position":"left","image_1":35090,"image_2":null,"video_file":null,"color":"","font_color":"","section_heading":"","module_content_1":"<h2>Options for RW Configuration<\/h2>\r\n<ul>\r\n \t<li>High efficiency integral droplet separator in PP material (requested for VDI 6022 hygienic configuration)<\/li>\r\n \t<li>Filling water pretreatment by U.V. lamp with 50\u03bcm and 5\u03bcm water filters<\/li>\r\n \t<li>Water high temperature alarm<\/li>\r\n \t<li>Air relative humidity sensor<\/li>\r\n \t<li>Air temperature sensor<\/li>\r\n \t<li>Multiple stage control with solenoid valves (up to 4 stage control)<\/li>\r\n \t<li>Water conductivity sensor<\/li>\r\n<\/ul>\r\n&nbsp;","module_content_2":"","module_content_3":"","accordion":null,"content_connector":null,"download_box_heading":"","downloads":null,"menu_item":[{"link":"","label":"Data Centers Home"},{"link":"","label":"Best-in-Class Cooling"},{"link":"","label":"How EvaPack<sup>\u00ae<\/sup> Works"},{"link":"","label":"DW Series"},{"link":"","label":"RW Series"},{"link":"","label":"Basic Control RW"},{"link":"","label":"Evaporative Pad"},{"link":"","label":"Models &amp; Selection"},{"link":"","label":"Products &amp; Services"},{"link":"","label":"Humidification &amp; Cooling Case Studies"},{"link":"","label":"Armstrong University Course on Evaporative Pad Adiabatic Humidifiers"}]},{"module":"side","content_type_1":false,"padding":"pad-bottom","background":false,"image_position":"right","image_1":47180,"image_2":null,"video_file":null,"color":"","font_color":"","section_heading":"","module_content_1":"<h2>Standard Components Supplied with EvaPack<sup>\u00ae<\/sup><\/h2>\r\nNote: The EvaPack<sup>\u00ae<\/sup> control panel is required for all electrical devices.\r\n<ul>\r\n \t<li>Water basin with draining and overflow piping|Evaporative cassettes (composed of EvaPack<sup>\u00ae<\/sup> evaporative pad and cassette frames in stainless steel AISI 304)<\/li>\r\n \t<li>Side and top frames in stainless AISI 304|Irrigation piping<\/li>\r\n \t<li>Dispersion manifold(s)<\/li>\r\n \t<li>Water pump<\/li>\r\n \t<li>Manual adjustment gate valve(s)<\/li>\r\n \t<li>Water draining valve<\/li>\r\n \t<li>Solenoid water filling valve<\/li>\r\n \t<li>Water level sensor<\/li>\r\n<\/ul>","module_content_2":"","module_content_3":"","accordion":null,"content_connector":null,"download_box_heading":"","downloads":null,"menu_item":null},{"module":"full","content_type_1":"standard","padding":"pad-both","background":"color","image_position":false,"image_1":null,"image_2":null,"video_file":null,"color":"#3d4052","font_color":"font-light","section_heading":"","module_content_1":"<h2 align=\"left\">Operation Sequences<\/h2>\r\n<p align=\"left\">This configuration is recommended when the available supplied water has low or medium hardness.<\/p>\r\n<p align=\"left\">For additional information, please consult the EvaPack<sup>\u00ae<\/sup> IOM manual:\u00a0 EvaPack \u2122 Series Evaporative Pad Adiabatic Humidifier\/Cooler Installation for RW and DW Configuration.<\/p>\r\n<p align=\"left\"><a href=\"https:\/\/armstronginternational.com\/wp-content\/uploads\/sites\/9\/IOM_EvaPackEvaporativeHumidifier_542_EN_20200701.pdf\" target=\"_blank\" rel=\"noopener\">Download Manual<\/a><\/p>\r\n\r\n<ul>\r\n \t<li>Water enters the basin, passing through the filling valve (1). The water level detector (7) controls the basin (2) filling, the pump (3) starting-up and the fill valve opening.<\/li>\r\n \t<li>The recirculation water pump (3) supplies water to the different dispersion manifolds (5). The water flow of each cassette (6) is adjusted with a manual gate valve (4). Calibrated orifices deliver water evenly over each media pad (6).<\/li>\r\n \t<li>Dry air passes through a corrugated bank of wetted cells media (6). Air is cooled and humidified.<\/li>\r\n \t<li>Excess water washes the evaporative pad, then falls (with minerals) into the water tank.<\/li>\r\n \t<li>Excess minerals are drained by the draining valve, minimizing water consumption and media scaling.<\/li>\r\n<\/ul>\r\n<p align=\"left\"><img class=\"alignnone wp-image-38706\" src=\"https:\/\/armstronginternational.com\/wp-content\/uploads\/sites\/9\/evapack-operation-sequence-diagram-recirculated-water-300x295.jpg\" alt=\"\" width=\"305\" height=\"300\" \/><\/p>\r\n<p align=\"left\"><a href=\"https:\/\/armstronginternational.com.br\/products-landing\/humidification-solutions\/humidification-health\/\">Products for Health and Humidification<\/a><\/p>","module_content_2":"","module_content_3":"","accordion":null,"content_connector":null,"download_box_heading":"","downloads":null,"menu_item":null},{"module":"submenu","content_type_1":false,"padding":"pad-top","background":"none","image_position":false,"image_1":null,"image_2":null,"video_file":null,"color":"","font_color":"","section_heading":"","module_content_1":"<section class=\"full-width pad-none \">\r\n<div class=\"container\">\r\n<h2 align=\"center\">Discover What Our Global Experience in Data Centers Can Do For You<\/h2>\r\n<\/div>\r\n<\/section>","module_content_2":"","module_content_3":"","accordion":null,"content_connector":null,"download_box_heading":"","downloads":null,"menu_item":[{"link":{"type":"url","value":"https:\/\/armstronginternational.com.br\/industries\/data-centers\/","title":"Data Centers","target":false},"label":"Data Centers Home"},{"link":{"type":"url","value":"https:\/\/armstronginternational.com.br\/industries\/data-centers\/","title":"Data Centers","target":false},"label":"Best-in-Class Cooling"},{"link":{"type":"url","value":"https:\/\/armstronginternational.com.br\/industries\/data-centers\/how-evapack-works\/","title":"How EvaPack<sup>\u00ae<\/sup> Works","target":false},"label":"How EvaPack<sup>\u00ae<\/sup> Works"},{"link":{"type":"url","value":"https:\/\/armstronginternational.com.br\/industries\/data-centers\/evapack-direct-water\/","title":"EvaPack<sup>\u00ae<\/sup> Direct Water","target":false},"label":"DW Series"},{"link":{"type":"url","value":"https:\/\/armstronginternational.com.br\/industries\/data-centers\/evapack-recirculated-water\/","title":"EvaPack<sup>\u00ae<\/sup> Recirculated Water","target":false},"label":"RW Series"},{"link":{"type":"url","value":"https:\/\/armstronginternational.com.br\/industries\/data-centers\/basic-control\/","title":"Basic Control","target":false},"label":"Basic Control RW"},{"link":{"type":"url","value":"https:\/\/armstronginternational.com.br\/industries\/data-centers\/evapack-evaporative-pad\/","title":"EvaPack<sup>\u00ae<\/sup> Evaporative Pad","target":false},"label":"Evaporative Pad"},{"link":{"type":"url","value":"https:\/\/armstronginternational.com.br\/industries\/data-centers\/evapack-selection\/","title":"EvaPack Series Evaporative Pad Adiabatic Humidifier","target":false},"label":"Models &amp; Selection"},{"link":{"type":"url","value":"https:\/\/armstronginternational.com.br\/products\/industry-data-centers\/","title":"Data Center Products","target":false},"label":"Products &amp; Systems for Data Centers"},{"link":{"type":"url","value":"https:\/\/armstronginternational.com.br\/company\/case-studies\/","title":"Case Studies","target":false},"label":"Humidification &amp; Cooling Case Studies"},{"link":{"type":"url","value":"https:\/\/armstronginternational.com\/courses\/evaporative-pad-humidifiers\/","title":"Armstrong University Course on Evaporative Pad Adiabatic Humidifiers","target":false},"label":"Armstrong University Course on Evaporative Pad Adiabatic Humidifiers"}]}]},"_links":{"self":[{"href":"https:\/\/armstronginternational.com.br\/en\/wp-json\/wp\/v2\/pages\/4938","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/armstronginternational.com.br\/en\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/armstronginternational.com.br\/en\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/armstronginternational.com.br\/en\/wp-json\/wp\/v2\/users\/5"}],"replies":[{"embeddable":true,"href":"https:\/\/armstronginternational.com.br\/en\/wp-json\/wp\/v2\/comments?post=4938"}],"version-history":[{"count":0,"href":"https:\/\/armstronginternational.com.br\/en\/wp-json\/wp\/v2\/pages\/4938\/revisions"}],"up":[{"embeddable":true,"href":"https:\/\/armstronginternational.com.br\/en\/wp-json\/wp\/v2\/pages\/4805"}],"wp:attachment":[{"href":"https:\/\/armstronginternational.com.br\/en\/wp-json\/wp\/v2\/media?parent=4938"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}